i Series II / iX Series II / iM Series II
Figure 3-2: RS232C Cable for PC Connection wiring diagram – Units without USB.
3.6.4 USB Interface
A standard USB Series B device connector is located on the rear panel for remote control. A
standard USB cable between the AC Source and a PC or USB Hub may be used.
Note: Use of the USB port to control more than one power source from a single PC is not
recommended, as communication may not be reliable. Use GPIB interface for
multiple power source control.
Figure 3-3: USB Connector pin orientation.
Pin
Name
Description
1
VBUS
+5 VDC
2
D-
Data -
3
D+
Data +
4
GND
Ground
Table 3-6: USB Connector pin out.