SCPI Command Operation

SG Series Programming

6-14

M550129-03 Rev K

Command

Description

SCPI

:RAMP <NRf> <NRf>

Sets the output current to ramp from the present value to the
specified value (first argument) in the specified time (second
argument). See Ramp Function description below.

N

:RAMP?

Returns 1 if the ramp is in progress, and 0 if the ramp is
completed.

N

:ABORt

Aborts ramping and clears trigger mode.

N

:ALL?

Returns the ramping status of all channels.

N

:HTRIGgered <NRf>

Sets the value of the output current to ramp to be
implemented when the hardware trigger is received.

N

:HTRIGgered?

Returns the value of the output current to ramp to be
implemented when the hardware trigger is received.

N

:TRIGgered <NRf>

<NRf>

Sets the output current to ramp from the present value to
the specified value (first argument) in the specified time
(second argument) upon the trigger command. See Ramp
description below.

C

:TRIGgered?

Returns the value that the output current is to ramp to (first
value) and the time that it is to ramp (second value) upon
the trigger command.

C

:TRIGgered

Sets the output voltage to the values stored by the
SOURce: CURRent:TRIGger:AMPLitude command.

C

:TRIGgered?

Returns the current level that will be set upon receipt of the
trigger.

C

:CLEar

Clears the value stored by the
SOURce:CURRent:TRIGger:AMPLitude command.

C

:AMPLitude <NRf>

Stores the value of the output current to be set when the
SOURce: CURRent:TRIGGered command is sent.

C

:AMPLitude?

Returns the stored value of the output current to be set
when the SOURce: CURRent:TRIGGered command is
sent.

C

:POWer

(in SGI only); see Section 6.13.2.

C

:POWer?

C

:TIMeout?

Returns the integer value 1 (timeout since last query) or 0
(no timeout) of the timeout status of the channel.

N

:VOLTage

Sets the output voltage of the supply in volts (default) or in
millivolts.

C

:VOLTage?

Returns the output voltage of the supply in volts or in
millivolts.

C

[:LEVel]

Sets the output voltage of the supply in volts (default) or in
millivolts.

C

[:LEVel?]

Returns the output voltage of the supply in volts or in
millivolts.

C

Advertising