1 operating modes – AMETEK SLD Series User Manual
Page 15

Sorensen SLD-Series DC Load
Introduction
M540075-01 Rev C
1-3
1.1.1 Operating
Modes
The operating modes of the SLD-series Electronic Load include Constant Current (CC) mode,
Constant Resistance (CR) mode, and Constant Voltage (CV) mode. The wide range dynamic
load with rise/fall current slew rate is available in CC mode only.
CC Mode:
(Constant Current mode)
With the operating mode of constant current, the SLD-series Electronic load will sink a
current in accordance with the programmed value regardless of the input voltage (see
Figure 1-5).
I
V
CC
LOAD
CURRENT
CURRENT SETTING
INPUT VOLTAGE
Figure 1-5 Constant Current Mode
CR Mode:
(Constant Resistance Mode)
At constant resistance mode; the SLD-series Electronic Load will sink a current linearly
proportional to the load input voltage in accordance with the programmed resistance
setting (see Figure 1-6).
I
V
LOAD
CURRENT
INPUT VOLTAGE
RESISTANCE
SETTING
Figure 1-6 Constant Resistance Mode