Operation

Sorensen SLD-Series DC Load

3-6

M540075-01 Rev C

ON/OFF selections or value changes.

•

The LED indicates the status of the Configuration function:

◦ lit = Configuration function is ON.

◦ not lit = Configuration function is OFF

15 LIMIT Key and ON/OFF LED

Scrolls among the parameters whose limits you can set.

•

The Limit key sequentially selects the following parameters to program their
settings:

◦ upper Voltage limit
◦ lower Voltage limit
◦ upper Current limit
◦ lower Current limit

◦ returns to OFF and the loop repeats

•

the Navigation keys, 13, are used with the Limit function to set the desired values.

•

The LED indicates whether limits are being programmed or not:

◦ lit = Limit function isON.

◦ not lit = Limit function is OFF.

16 SHORT Key and ON/OFF LED

•

The SHORT key toggles the short circuit of the input terminal On and Off.

•

LED indicates the ON/OFF status of the short circuit

◦ lit = ON

◦ not lit = OFF

17 DUAL V/A Key and ON/OFF LED

This key is used to display the dual voltage or current.

•

DUAL V/A scrolls in the following sequence:

◦ Voltage for Channel A in upper display (7) and for Channel B in lower display (8)
◦ Current for Channel A in upper display and for Channel B in lower display

◦ returns to OFF and the loop repeats

•

The LED indicates whether or not the digital meter is displaying dual voltage or
current for channels A and B.

◦ lit = dual voltage or current is being displayed in the digital meter display

◦ not lit = OFF

•

Associated LEDs:

◦ V = Value displayed is in Volts

◦ A = Value displayed is in Amps