Table 2-2, Critical temperature spots, Hardware preparation and installation – Artesyn COMX-P40x0 ENP2 Installation and Use (August 2014) User Manual
Page 28

Hardware Preparation and Installation
COMX-P40x0 ENP2 Installation and Use (6806800R95B)
28
The following table summarizes components that exhibited significant temperature rises and
their maximum allowable operating temperature. These components should be monitored in
order to assess thermal performance during customized thermal solution development.
Table 2-2 Critical Temperature Spots
Component Identifier
Heat Dissipation Power (W)
Maximum Allowable Temperature (°C)
CPU: P4080
20.5
CPU: 105 (Tj)
CPU: P4040
16.8
CPU: 105 (Tj)
Memory SDRAM
3
95 (Tc)
GbE Transceiver:
BCM5482
0.86
125 (Tj)
Row 4, Note: For modules with Gigabit Ethernet port options.
System Overheating
Improper cooling can lead to system damage and void the manufacturer's warranty.
Personal Injury
During operation, hot surfaces may be present on the heat sinks and the components of the
product.
To prevent injury, do not touch any of the exposed components or heatsinks on the product
when handling.