2 unpacking and inspecting the enclosure, Table 2-3, Current drawn – Artesyn COMX-P40x0 ENP2 Installation and Use (August 2014) User Manual
Page 29: Table 2-4, Comx-p4080-4g-e-enp2, Hardware preparation and installation

Hardware Preparation and Installation
COMX-P40x0 ENP2 Installation and Use (6806800R95B)
29
Power Requirements
This board is designed to operate with the input voltages and currents as defined in the
following tables.
2.2
Unpacking and Inspecting the Enclosure
Read all notices and cautions prior to unpacking the product.
Table 2-3 Current Drawn
State
12v
VCC_RTC
Idle
2.81A
100 uA
Full Loading (Linux)
2.91A
100 uA
Table 2-4 COMX-P4080-4G-E-ENP2
Volts
Amps
Power
12
2.6
31.2
Total Power dissipation (W)
31.2
Damage of Circuits
Electrostatic discharge and incorrect installation/removal of the product can damage
circuits or shorten their life.
Before touching the product make sure that you are working in an ESD-safe
environment with protective equipment such an ESD wrist strap and ESD shoes. Hold
the product by its edges and do not touch any components or circuits.