Firmware upgrades – Artesyn PrAMC-7211 PNE3.0 Software Installation Guide (June 2014) User Manual
Page 63

Firmware Upgrades
PrAMC-7211-PNE3.0 Software Installation Guide (6806800L07B)
63
root@PrAMC-7211:~# fcu -uf /opt/motorola/rom/pramc-7211-cpu.fri
PTM control block init, PTMID get failed
This ipmc device supports legacy non-HPM.1 upgrade protocol.
UPGRADING BANK B ...
Booting from BANK B is highly suggested before upgrading the other bank.
********************[[[[[REPORT BEGIN]]]]]********************
OPERATION : Verify
RESULT : NOTICE
MESSAGE : forcing partrevision
OPERATION : Verify
RESULT : SUCCESS : compatible image found
MESSAGE : OEM:Emerson PROD:PrAMC-7211 PN: 0106824E02C REV: Rev C
VER:1.8 NAME:PHOENIX-BIOS
OPERATION : Write
RESULT : SUCCESS UPGRADING
MESSAGE : pramc-7211-cpu:Emerson:PrAMC-7211:0106824E02C:Rev
C:PHOENIX-BIOS:1.8
********************[[[[[ REPORT END ]]]]]********************
3. If you want to upgrade the current active bank, then mark the current standby bank to be
booted and reboot. Follow step
to upgrade this new inactive bank.
fcu -mb <BANK> -d pramc-7211-cpu