Table 5-8, Ipmi functions list – Artesyn RTM-ATCA-736x-DD Installation and Use (June 2014) User Manual
Page 64

IPMI Functions List
RTM-ATCA-736X-DD Installation and Use (6806800L82C)
64
At present, the OEM manufacturing data is expected to contain four entries, beginning at
offset 0x00
1. Manufacturer, Null terminated (0x00)
2. Product Name, Null terminated (0x00)
3. Part/Model Number, Null terminated (0x00)
4. Serial Number, Null terminated (0x00)
5.4.1.4
Write OEM Manufacturing Data Contents in DCA EEPROM
Each Drive Carrier Assembly (DCA) includes an EEPROM, with a 128 byte region reserved for
FRU data storage. The region may contain data deemed relevant to the manufacturer. Users
may read the FRU data region 8 bytes at a time. Use this command to write bytes to the FRU
data region at a given offset.
Table 5-8 IPMI Raw Command to Read FRU Data from Hard Disk Assembly
Raw command
Description
netfn
0x2E
cmd
0xA3
data
0xA4 0x76 0x00 0xZZ xYY [8 data bytes]
Where 0xZZ indicates the disk drive:
0x01 is disk#1, 0x02 is disk#2.
Where 0xYY is byte count offset, (0x00-0x77)
Any other 0xZZ value will trigger completion code 0xCC
Return code
0x00 - Success
0xC9 = IPMI PARAMETER OUT OF RANGE, I2C write failed, invalid address
0xCC - Invalid Data in Request
0xD5 = Command not supported in present state
Return Data
0xA4 0x76 0x00