5 communication mechanisms for disk extraction, Table 5-9, Disk eject jumper position vs. function – Artesyn RTM-ATCA-736x-DD Installation and Use (June 2014) User Manual
Page 65: Figure 5-1

IPMI Functions List
RTM-ATCA-736X-DD Installation and Use (6806800L82C)
65
5.5
Communication Mechanisms for Disk Extraction
The RTM includes two disk eject request buttons located on the RTM panel. When pressed, the
behavior of the RTM is governed by the state of jumper identified as HDR500. The diagram
below shows the location of the eject buttons and header.
Disk eject behavior differs by the position of jumper HDR500.This table defines the operations
that take place when the drive eject request button is depressed.
Figure 5-1
Locations of Disk Eject Jumper and Disk Eject Buttons
Table 5-9 Disk Eject jumper Position vs. Function
Jumper/Header
(HDR500)
Extraction Type
Description
None
Slave
In this configuration, the host blade must grant
the RTM explicit permission for drive removal.
This permission is conducted using custom
commands exchanged between the MMC on the
RTM and the Host.
1-2