R (white), R (black), Ratio – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 81: Ansi symbol grade

06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
81
R (white)
9864
Reflectance.
¯
Only if
OLV PARAMETER > Cancel. printing
= Enabled.
¯
Condition: Value >= Limit.
xxx
Setting range: -1 to 100; Unit interval: 1; -1 = No checking.
R (black)
9864
Reflectance.
¯
Only if
OLV PARAMETER > Cancel. printing
= Enabled.
¯
Condition: Value <= Limit.
xxx
Setting range: -1 to 100; Unit interval: 1; -1 = No checking.
Ratio
9864
¯
Only if
OLV PARAMETER > Cancel. printing
= Enabled.
¯
Condition: Value >= Limit.
xxx
Setting range: -1 to 99; Unit interval: 1; -1 = No checking.
ANSI symbol grade
9864
¯
Only if
OLV PARAMETER > Cancel. printing
= Enabled.
¯
Condition: Value >= Limit.
For most applications, you only need to set this parameter. The previously
listed parameters are checked automatically according to ANSI grade.
xxx
Setting range: -1 to 40; Unit interval: 1; -1 = No checking.
Value
ANSI Grade
0-5
F
5-15
D
15-25
C
25-35
B
35-40
A
[12] ANSI symbol grades