Dp interface, Interface type, Start delay – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 89

06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
89
DP INTERFACE
¯
These parameters only appear in the parameter menu when a USI board
is installed.
Interface type
9864
¯
Only with USI board.
Sets the machine to use applicator.
USI interface
Setting for direct dispensing.
USI applicator
Setting for operation of an applicator with additional PLC.
Start delay
9864
¯
Only with USI board.
This parameter sets the distance between the product sensor (photoelectric
switch) and the dispensing edge. The delay time is calculated from the Start
delay distance and the conveyor speed (or print speed if using direct
application).
xxx.x mm
Setting range: 0.0 to 999.9 mm; Unit interval: 0.1 mm;
Default setting: 0 mm
¯
The start delay setting works with one of the following parameter Start
Print Mode settings:
Parameter
Setting
Start print mode
Pulse falling
Pulse rising
Pulse fall/ris
[15] To use Start delay, set one of the Start Print Mode settings.