6 general overview (ax5190 and ax5191) – BECKHOFF AX5000 60 A - 170 A User Manual

Page 20

Advertising
background image

4 Product description

BECKHOFF

Drive Technology

20

Version: 1.4

AX5000

4.6

General overview (AX5190 and AX5191)

Item description:

No Designation

No Designation

1 X4x – optional slot for expansion cards

9 X14 – sensor for motor temperature

and brake

2 X3x – optional slot for safety card

10 DC link output (890 V DC voltage)

Connection for external brake resistor

3 X11 – feedback connection, encoder

11 Motor connection (U,V,W,PE)

4 X06 – connection for digital inputs and outputs 12 X04 – socket for EtherCAT input

5 Navigation rocker

13 Labeling field

6 Labeling field

14 Display

7 X05 – socket for EtherCAT output

15 X12 – feedback connection, resolver

8 X03 – power supply 24 V DC input

16 X01 – mains supply 400 – 480 V

DANGER

Max. 890 V DC voltage at the

DC link terminals. Dangerous

voltage may be present for

30 minutes after the device is

switched off. The device is

safe once the voltage has

fallen below 50 V.

(Check voltage)

Advertising