2 electrical installation – BECKHOFF AX5000 60 A - 170 A User Manual

Page 33

Advertising
background image

BECKHOFF

Drive Technology

5 Installation

AX5000

Version: 1.4

33

5.2

Electrical installation

UL-Listing!
It is essential to observe chapter 3.3 if you wish to operate an AX5000 in an

economic area that requires a UL-Listing.

DANGER

Serious risk of injury through electric shock!
Due to the DC link capacitors dangerous voltage may persist at the DC link

contacts “ZK+ and ZK-“ and “RB+ and RB-“ after the servo drive has been

disconnected from the mains supply. After disconnecting the servo drive

wait at AX5160/AX5172 15 minutes, at AX5190/AX5191 30 minutes and at

AX5192/AX5193 45 minutes and measure the voltage at the DC link

contacts ZK+ and ZK-. The device is safe once the voltage has fallen below

50 V.

WARNING

Caution – Risk of injury through electric shock!

Before installation, wiring and commissioning it is essential to read the

section on "Safety".

Before installing, uninstalling or connecting the servo drive and the

motors please note the following:

- Remove all relevant mains fuses.

- Switch off the main system switch and secure it with a lock.

- Put up a warning sign.

The control and power connections for the motors may be live, even if

the motor is prevented from rotating by the internal brake.

Attention

Destruction of the equipment!

Check the rated voltage and current of the servo drive and the connected

motors.

When the AX5000 is disconnected from the mains supply (emergency

stop, mains contactor etc.), query the status of the IDN "P-0-0205" (see

documentation of the “IDN-Description”) before starting again or

Advertising