2 electrical installation – BECKHOFF AX5000 60 A - 170 A User Manual

Page 33

Advertising
background image

BECKHOFF

Drive Technology

5 Installation

AX5000

Version: 1.4

33

5.2

Electrical installation

UL-Listing!
It is essential to observe chapter 3.3 if you wish to operate an AX5000 in an

economic area that requires a UL-Listing.

DANGER

Serious risk of injury through electric shock!
Due to the DC link capacitors dangerous voltage may persist at the DC link

contacts “ZK+ and ZK-“ and “RB+ and RB-“ after the servo drive has been

disconnected from the mains supply. After disconnecting the servo drive

wait at AX5160/AX5172 15 minutes, at AX5190/AX5191 30 minutes and at

AX5192/AX5193 45 minutes and measure the voltage at the DC link

contacts ZK+ and ZK-. The device is safe once the voltage has fallen below

50 V.

WARNING

Caution – Risk of injury through electric shock!
•

Before installation, wiring and commissioning it is essential to read the

section on "Safety".

•

Before installing, uninstalling or connecting the servo drive and the

motors please note the following:

- Remove all relevant mains fuses.

- Switch off the main system switch and secure it with a lock.

- Put up a warning sign.

•

The control and power connections for the motors may be live, even if

the motor is prevented from rotating by the internal brake.

Attention

Destruction of the equipment!
•

Check the rated voltage and current of the servo drive and the connected

motors.

•

When the AX5000 is disconnected from the mains supply (emergency

stop, mains contactor etc.), query the status of the IDN "P-0-0205" (see

documentation of the “IDN-Description”) before starting again or

Advertising