WARNING

Caution – Risk of injury!
Electronic equipment is not fail-safe. The machine manufacturer is

responsible for ensuring that the connected motors and the machine are

brought into a safe state in the event of a fault in the drive system.

Please be aware each time before commissioning the AX5000 that connected motors can

make uncontrolled movements, which cannot always be prevented even by the AX5000’s

integrated diagnostic system, or may permit uncontrolled movements until the diagnostic

system responds. Analyse your system and take suitable precautions to prevent damage

being caused by these uncontrolled movements.

Potential causes of uncontrolled movements:

The diagnostic system of the AX5000 is equipped with complex plausibility checks, which

constantly monitor installation, operation, parameterisation and operation and, if necessary,

interrupt them with a diagnostic message. The points listed below are naturally also

monitored as standard, but it is not possible to include all eventualities; therefore, with

respect to the following points, you must always consider whether the driven axes can only

perform permissible movements.

Incorrect commutation results (e.g. during wake & shake), It is essential to observe

chapter “AX5000 User manualcommissioningcommutation methodscommutation

error “F2A0”” on our Homepage.

Specific caution with synchronous motors of third parties: always execute the

command „P-0-0166“ without load when changing the motor or feedback or when

changing the SysMan-file (.TSM) and evaluate the result. Correct the commutation offset if

applicable., as described in chapter

“AX5000 User manual Commissioning Commutation methods”.

Input of invalid parameters

Measuring transducer and/or signal transducer defective or incorrectly adjusted

Cables defective or not adequately screened

Incorrectly attached sensors

CAUTION

Increased attention in the case of vertical axes!
When commissioning vertical axes, the risk consideration described above

is to be carried out with particular care. An uncontrolled movement can

mean the sudden falling down of a load in this case.