7 general overview (ax5192 and ax5193) – BECKHOFF AX5000 60 A - 170 A User Manual

Page 21

Advertising
background image

BECKHOFF

Drive Technology

4 Product description

AX5000

Version: 1.4

21

4.7

General overview (AX5192 and AX5193)

Item description:

No Designation

No Designation

1 X4x – optional slot for expansion cards

9 X14 – sensor for motor temperature

and brake

2 X3x – optional slot for safety card

10 X07 – External brake resistor

3 X11 – feedback connection, encoder

11 DC link output (890 V DC voltage)

4 X06 – connection for digital inputs and outputs 12 Motor connection (U,V,W,PE)

5 Navigation rocker

13 X04 – socket for EtherCAT input

6 Labeling field

14 Labeling field

7 X05 – socket for EtherCAT output

15 Display

8 X03 – power supply 24 V DC input

16 X12 – feedback connection, resolver

DANGER

Max. 890 V DC voltage at the

DC link terminals. Dangerous

voltage may be present for

45 minutes after the device is

switched off. The device is

safe once the voltage has

fallen below 50 V.

(Check voltage)

17 X01 – mains supply 400 – 480 V

Advertising