Dot Hill Systems II 200 FC User Manual

Page 105

Advertising
background image

Chapter 6 Checking LEDs

6-7

The I/O controller module LEDs and their color definitions are shown in Table 6-4.

Table 6-4 I/O Controller Module and Battery Module LEDs

LED

Purpose

LED Color Definition

Battery

Status of battery

Solid green – Battery charged
Blinking green – Battery charging
Solid amber – Battery failed

Activity

I/O activity of host
and disk ports

Off – Not busy (no I/O activity)
Blinking green – Busy (active I/O)

Cache

Status of memory
cache

Off – Clean cache
Blinking green – Dirty cache; data is in
memory and is not written to disk yet

Ethernet link
(active
controller)

Status of Ethernet
link

Solid amber – Active link
Off – Inactive connection

Ethernet link
(inactive
controller)

Status of Ethernet
link

Off – Active connection on inactive
controller, or inactive connection

Ethernet active

Status of Ethernet
activity

Blinking green – Busy

RAID controller

Status of controller
on I/O controller
module

Blinking green – Good (primary controller)
Solid green – Good (secondary controller)
Solid amber – Failed RAID controller or I/O
module

SFP link (L)

SFP link status

Solid green – Active good FC Connection
Off – Empty or failed FC connection

SFP speed (S)

SFP speed status

Solid green – 2 Gbit
Off – 1 Gbit

Advertising