8-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Note –

It is important to know the cause of the error condition because how you

silence the alarm depends on the cause of the alarm.

To silence the alarm, perform the following steps:

1. Check the error messages, event logs, and LED activity to determine the cause of the

alarm.
Component event messages include but are not limited to the following:

■

SES/PLD firmware mismatch

■

Temperature

■

Cooling element

■

Power supply

■

Battery

■

Fan

■

Voltage sensor

Caution –

Be particularly careful to observe and rectify a temperature failure alarm. If

you detect this alarm, shut down the controller. Shut down the server as well if it is
actively performing I/O operations to the affected array. Otherwise, system damage
and data loss can occur.

See Appendix C for more information about component alarms.
Controller event messages include but are not limited to the following:

■

Controller

■

Memory

■

Parity

■

Drive SCSI Channel

■

Logical drive

■

Loop connection

Refer to the “Event Messages” appendix in the SANnet II Family RAID Firmware
User’s Guide
for more information about controller events.