8-6 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Note –

It is important to know the cause of the error condition because how you

silence the alarm depends on the cause of the alarm.

To silence the alarm, perform the following steps:

1. Check the error messages, event logs, and LED activity to determine the cause of the

alarm.
Component event messages include but are not limited to the following:

SES/PLD firmware mismatch

Temperature

Cooling element

Power supply

Battery

Fan

Voltage sensor

Caution –

Be particularly careful to observe and rectify a temperature failure alarm. If

you detect this alarm, shut down the controller. Shut down the server as well if it is
actively performing I/O operations to the affected array. Otherwise, system damage
and data loss can occur.

See Appendix C for more information about component alarms.
Controller event messages include but are not limited to the following:

Controller

Memory

Parity

Drive SCSI Channel

Logical drive

Loop connection

Refer to the “Event Messages” appendix in the SANnet II Family RAID Firmware
User’s Guide
for more information about controller events.