Cadac CDC four User Manual

Page 32

Advertising
background image

32

Revision 1 2012-13

CDC FOUR

Remainder of input channel - CAM/screen control

All other input channel functions are controlled from either the CAM or the screen.

In CHN mode, the screen displays a virtual channel strip with a full set of controls

which may be adjusted using the ADJUST knob.

Input stage:
TRIM
- input gain trim, range -48 to +12 dB. Default setting is 0 dB.

48v – enables 48 V phantom power at the mic input. Default is Off.

REV – phase reverse switch. Default is Off.

HPF (button) – enables the variable-frequency high-pass filter. Default is Off.

HPF (rotary) – adjusts the cut-off frequency of the high-pass filter. Range is 14 Hz

to 400 Hz, slope 12 dB/oct. Default setting is the minimum: 14 Hz.

Noise gate:
THR
– adjusts the threshold of the channel’s noise gate in the range from “off”

(below -74.9 dB) to -20 dB. Default setting is -60 dB. When the gate is in circuit,

signals below the threshold level will be rejected; the signal level needs to exceed

the threshold in order to open the gate.

IN – switches the noise gate into the signal chain. Default is Out.

NOTE: Additional Gate parameters are available from the Dynamics Details

screen page – see “Dynamics detail” on page 54.

Compressor:
THR
– adjusts the threshold of the channel’s compressor in the range -48 dB to

0 dB. Default setting is -12 dB. Signals below the threshold will not be com-

pressed. Signals above the threshold will have their levels reduced to a degree

determined by the ratio control (below).

RAT – adjusts the compression ratio between 1:1 to 20:1. Default setting is 1:1

(i.e., no compression). A compression ratio of 1:1 implies zero compression;

higher values will proportionately reduce the dynamic range of the signal, e.g., at

a setting of 2:1, signals 10 dB above the threshold will be compressed to be only

5 dB above the threshold.

LVL – adds gain to compensate for compressor action. Range is -12 dB to +12

dB. Default setting is 0 dB.

IN – switches the compressor into the signal chain. Default is Out.

AUT – in Auto mode, the compressor’s Attack and Release time constants are

not fixed, but programme-dependent, and set by an algorithm which makes the

compressor’s action unobtrusive. In Manual mode, the time constants may be

adjusted from the Dynamics Detail page (see NOTE below).

+

-

+

-

TRIM

HPF

48V

REV

HPF

S

mS

+

-

+

-

+

-

+

-

20:1

1:1

LIM

THR

DLY

COMP

GATE

LVL

RAT

THR

THR

IN

IN

AUT

VIN

IN

IN

BYP

PST

S

mS

+

-

+

-

+

-

+

-

20:1

1:1

LIM

THR

DLY

COMP

GATE

LVL

RAT

THR

THR

IN

IN

AUT

VIN

IN

IN

BYP

PST

Advertising