The System page provides controls for the CDC FOUR’s oscillator, talkback

routing, monitor control functions and Solo system control. The page is divided

in four Modules, plus an area on the right for PFL and AFL metering. Most of the

controls on these pages have no hardware equivalents, and are selected and

adjusted by using the cursor keys and the ADJUST control.

Oscillator
The CDC FOUR’s line-up oscillator can generate a sine wave, white noise or pink

noise for system test or alignment, or for room equalisation purposes.

The oscillator is enabled by pressing Softkey 1 (OSC On/Off). The Type button

selects the oscillator output signal – Sine, White (Noise) or Pink (Noise). When

Sine is selected, a Freq control becomes available; in this mode, the oscillator

has a range from 10 Hz to 10 kHz. The Oscillator output level is adjusted with the

OSC Level control.

The routing buttons allow the oscillator signal to be routed to any combination of:

L & R

Stereo master buss

1 to 4

Groups 1 to 4

A1 to A8

Aux busses 1 to 8