Connection to the gas main must be performed by a qualified technician, in
compliance with the current laws in force.
Be careful when flexible pipes are used that they do not come into contact with
moving parts.
To maintain the tickness of 3 cm, the hob is fitted with a channel to contain the
connection pipe.
The gas inlet union can be turned in the direction required after the union elbow
“C”-nipple “A” connection, or after the union elbow “C”-nut “A” connection, has
been slackened with two spanners (figure 25).
Never put in the horizontal or vertical position.

IMPORTANT:

a

Never attempt to turn the elbow “C” without having first slackened
off the relative lock nipple “A” or lock nut “A”.

a

The seal “F” and the biconical gasket “B” (fig. 23-24) guarantees the
seal of the gas connection. It is recommended that they be replaced
whenever they shown even the slightest deformation or
imperfection.

a

After connecting to the mains, check that the couplings are correctly
sealed, using soapy solution, but never a naked flame.

a

The connection with rigid metal pipes should not cause stresses to
the hob base.

a

If using flexible metal pipes, make sure thay are not squashed, and
do not come into contact with moving parts.

a

Any flexible pipes must be so installed as to be easily enspected
along their whole length. They must be changed before the expiry
date (printed on the pipe itself) and not excees 2 metres in length.