3.6.2.2 AC Operation (Standard) – Replacing Fuses

FOR  CONTINUED  OPERATOR  SAFETY,  ALWAYS  REPLACE  THE  FUSES  WITH  THE 
CORRECT TYPE AND RATING. 

The  MCED‐100  uses  two  120/240VAC  T2A  5x20mm  slow‐blow  fuses  –  one  each  for  line  and 
neutral connections. The fuses are contained within a fuse holder that is press‐fit into the body 
of the IEC power module (Figure 3‐5). 
 
 
 
 
 
 
 
 
 
 
 

 
 

Figure 3-7. AC Fuse Replacement

 
To replace the fuses: 
 

DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING! 

 

First, unseat the fuse holder from the IEC power module. 

 

o

Use the slot to pry the holder outward from the IEC power module.  
 

o

Pull the holder straight out, and then swing the holder away from the module.  

 

Then, remove and replace the fuses as needed. 

 

o

Use T2A fuses for standard operation. 

 

Finally, re‐seat the fuse holder in the IEC power module. 