Comtech EF Data CPA User Manual

Page 55

Advertising
background image

CPA C-Band Indoor Solid State Power Amplifier

Revision 1

Updating Firmware

MN/CPA-IN.IOM

4–9

o If using Serial Remote Control, type the “<0/IPA?” remote query (without quotes)

at the command prompt. The unit returns the configured IP Address.

•

Once the IP Address is known – use Command-line to PING: Type “ping

xxx.xxx.xxx.xxx” at the Command-line prompt (where ‘xxx.xxx.xxx.xxx’ is the unit IP

Address).

The response should confirm whether the unit is properly connected and

communicating.

2. Use Command-line to transfer (FTP) the files from the user PC to the CPA:

•

Type "ftp xxx.xxx.xxx.xxx" (where ‘xxx.xxx.xxx.xxx’ denotes the unit IP Address).

•

Type “bin” to set the binary transfer mode.

•

Type "prompt" and then type "hash" to facilitate the file transfers.

•

Type "put FW-0000086x_ISSPA_#_#_#.bin bulk:" (where ‘#_#_#’ denotes the firmware

version number) at the Command-line prompt, without quotes, to begin the file

transfer. The destination “bulk:” must be all lower-case.

Wait while the file transfers. During this time, the CPA front panel will report:

Programming APP flash…
Please wait…

The process sequences through several blocks – this will take several minutes. When the

process is complete, the CPA front panel will display:

CPA-XXX-XXXX-X
Ver. X.X.X SNXXXXXXXXX

•

Type "bye" to terminate the FTP session, and then close the Command-line window.

3. Recycle the CPA power and wait for the unit to reboot.

Advertising