3 . I n s t r u c t i o n S e t

3 - 3 1 9

API Mnemonic Operands

Function

132

D TAN P

Tangent

Controllers

ES2/EX2 SS2 SA2

SE

SX2

Bit Devices

Word devices

Program Steps

Type

OP

X Y

M S K H KnX KnY KnM KnS T C D E F

S

*

*

*

D

*

DTAN, DTANP: 9 steps

PULSE 16-bit 32-bit

ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2

Operands:

S: Source device (0°≦S<360°) D: Operation result

Explanations:

1.

TAN instruction performs tangent operation on S and stores the result in D.

2.

The value in S can be set as radian or degree by flag M1018.

3.

M1018 = OFF, radian mode. RAD = degree ×π/180.

4.

M1018 = ON, degree mode. Degree range: 0°≦degree<360°.

5.

Flag: M1018 (Flag for Radian/Degree)

6.

See the figure below for the relation between the radian and the operation result

R

S

-2

3
2

-2

2

3
2

2

2

-

1

-1

0

-

S: Radian

R: Result (TAN value)

7.

If operation result in D is 0, Zero flag M1020 = ON.

Program Example 1:

M1018 = OFF, radian mode. When X0 = ON, DTAN instruction performs tangent operation on the

radian value in (D1, D0) and stores the TAN value in (D11, D10) in binary floating format.

M1002

RST

M1018

X0

DTAN

D0

D10