3 - 4 3 4

API Mnemonic

Operands

Function

194

D CIMA

2-Axis Absolute

Position Arc

Interpolation

Controllers

ES2/EX2 SS2 SA2

SE

SX2

Bit Devices

Word devices

Program Steps

Type

OP

X Y M S

K H

KnX

KnY KnM KnS T C D E F

S

1

* *

*

S

2

* *

*

S

*

D

*

DCIMA: 17 steps

PULSE 16-bit 32-bit

ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2 ES2/EX2 SS2

SA2

SE

SX2

Operands:

S1: Number of output pulses of X axis S2: Number of output pulses of Y axis S:

Parameter setting D: Pulse output device

Explanations:

1. For ES2/EX2 models, only V1.20 or above supports the function.

2. The instruction only supports the pulse output type: Pulse / Direction.

3. S

1

and S

2

specify the number of output pulses (absolute positioning) on X axis (Y0) and Y axis

(Y2). Range: -2,147,483,648 ~ +2,147,483,647. When S

1

and S

2

are bigger than PV of pulse

output in CH0 (D1031 High, D1030 low) / CH1 (D1337 high, D1336 low), pulse output will

operate in positive direction and the direction signal output Y1, Y3 will be OFF. When S

1

and

S

2

are smaller than PV of pulse output, pulse output will operate in negative direction and the

direction signal output Y1, Y3 will be ON.

4. For the rest of the explanations on the instruction, special D and special M, please refer to API

193 DCIMR instruction.

Program Example 1:

1. Draw an ellipse as the figure below.

Y

X

(

)

16 00 0,2 20 00

(

)

32 00 0,0

(

)

0,0

(1 6 00 0,- 22 00 0)

2. Steps:

a) Set the four coordinates (0,0), (16000, 22000), (32000, 0), (16000, -22000) (as the figure