Insulating liner, Installation fig. 2-1 – Fire Magic Accessory & Legacy Insulating Liner User Manual

Page 2

Advertising
background image

2

L-C2-04309

REV 5 - 0912210954

WARNING: Use this insulating liner only

with the matching outdoor
gas appliance as indicated
in Table 1.

Dimensions shown (A, B, and C) are
for cabinet cut-out dimensions for the
liner. The dimensions do not include
additional allowance for counter tops
or cabinet facings (see Fig. 2-1).

1. Position the rear support hanger 2" from the back of the cut-out and with the horizontal surface of the hanger

fl ush with the bottom of the cut out as shown in Fig. 2-1. Fasten securely in place with fl at head screws (not
provided) into the sides on the enclosure.

2. Position the front support hanger 3" from the front of the enclosure and at the same level as the rear one.

Secure into place with fl at head screws into the sides of the enclosure.

3. Place the insulating liner on top of the support hangers (as shown in Fig. 2-1). Place the insulating liner

tightly against the back of the cabinet opening.

MODEL

SERIES

LINER

MODEL

C a b i n e t C u t - o u t d i m e n s i o n s

A X B X C*

(front-back) x (side-side) x (top-bottom*)

(Deluxe)

11 series

3100-50

19-

3

/

8

" x 28" x 12-

1

/

4

"

(Power Burner)

19 series

3278-50

20-

3

/

4

" x 22-

5

/

8

" x 12"

(Searing Burner)

3287-1(P)

3287-50

24-

3

/

4

" x 18-

3

/

8

" x 12"

Table 1 - Cut-out by model

INSTALLATION

Fig. 2-1

Insulating

liner

Screws
(provided by
installer)

Cabinet

enclosure

Rear support hanger

Front

support hanger

(in place)

C

B

5"

A

4"

3"

To install and operate the actual Fire
Magic outdoor gas appliance, please refer
to the installation and operating instructions
and safety precautions shipped with the
appliance.

2"

Place the front support
hanger 3" from the front
of the enclosure.

Place the rear support
hanger 2" from the rear
of the cut-out.

Secure support

hangers into sides

of enclosure

Overall dimensions
and appearance
vary with model.

Some liners
have an open
bottom.

*Important: Allow for a one inch clearance below the

cutout for the support hanger extensions
(see below).

* 1" clearance below

cutout needed for

hanger extensions.

Advertising