Hwx user instructions english - 07/14, Page 24 of 40 – Flowserve HWX Worthington User Manual

Page 24

Advertising
background image

HWX USER INSTRUCTIONS ENGLISH - 07/14

Page 24 of 40

M45

3375

(2489)

4875

(3596)

4950

(3651)

1425 (1051) 1800 (1328)

7050

(5200)

M48

4084

(3012)

5899

(4351)

5990

(4418)

1724 (1272) 2178 (1606)

8530

(6292)

M64

9750

(7192) 14083 (10388) 14300 (10548) 4117 (3037) 5201 (3836) 20370 (15025)

M68

11768 (8680) 16998 (12538) 17260 (12731) 4969 (3665) 6277 (4630) 24580 (18130)

M76

25230 (18610) 8270 (6100)

Above mentioned torques are for all screwed unions, which works under dynamical load. For all other
connections you can use a corresponding smaller torque.
Anchor bolts are usually made of 4.6 material. Tightening torques indicated in above table shall not be
exceeded.