Hwx user instructions english - 07/14, Page 24 of 40 – Flowserve HWX Worthington User Manual
Page 24
Advertising

HWX USER INSTRUCTIONS ENGLISH - 07/14
Page 24 of 40
M45
3375
(2489)
4875
(3596)
4950
(3651)
1425 (1051) 1800 (1328)
7050
(5200)
M48
4084
(3012)
5899
(4351)
5990
(4418)
1724 (1272) 2178 (1606)
8530
(6292)
M64
9750
(7192) 14083 (10388) 14300 (10548) 4117 (3037) 5201 (3836) 20370 (15025)
M68
11768 (8680) 16998 (12538) 17260 (12731) 4969 (3665) 6277 (4630) 24580 (18130)
M76
25230 (18610) 8270 (6100)
Above mentioned torques are for all screwed unions, which works under dynamical load. For all other
connections you can use a corresponding smaller torque.
Anchor bolts are usually made of 4.6 material. Tightening torques indicated in above table shall not be
exceeded.