MENBLOC USER INSTRUCTIONS ENGLISH 71576296 - 02/13

Page 18 of 40

flowserve.com

PUMP TYPE

Suction

DN

Discharge

DN

Forces

Moments

Fv max

Fh max

ΣΣΣΣ

Mt max

mm

in.

mm

in.

daN

lbf

daN

lbf

m.daN

lbf.ft

50-32-125

50

2”

32

1”1/4

125

281

95

214

20

148

50-32-160

50

2”

32

1”1/4

125

281

95

214

17

125

50-32-200

50

2”

32

1”1/4

125

281

95

214

17

125

50-32-200L

50

2”

32

1”1/4

125

281

95

214

17

125

65-40-125

65

2”1/2

40

1”1/2

135

304

100

225

22

162

65-40-160

65

2”1/2

40

1”1/2

135

304

100

225

22

162

65-40-200L

65

2”1/2

40

1”1/2

135

304

100

225

20

148

65-40-250

65

2”1/2

40

1”1/2

135

304

100

225

25

185

65-40-250L

65

2”1/2

40

1”1/2

135

304

100

225

25

185

65-50-125

65

2”1/2

50

2”

135

304

100

225

22

162

65-50-160

65

2”1/2

50

2”

135

304

100

225

22

162

65-50-200L

65

2”1/2

50

2”

135

304

100

225

20

148

65-50-250L

65

2”1/2

50

2”

135

304

100

225

25

185

80-65-125

80

3”

65

2”1/2

145

326

105

236

27

199

80-65-160

80

3”

65

2”1/2

145

326

105

236

27

199

80-65-200L

80

3”

65

2”1/2

145

326

105

236

27

199

80-65-250L

80

3”

65

2”1/2

145

326

105

236

27

199

80-65-315

80

3”

65

2”1/2

145

326

105

236

27

199

100-80-160

100

4”

80

3”

180

405

125

281

47

347

100-80-200L

100

4”

80

3”

180

405

125

281

47

347

100-80-250L

100

4”

80

3”

180

405

125

281

47

347

100-80-315

100

4”

80

3”

180

405

125

281

47

347

125-100-200L

125

5”

100

4”

320

720

190

427

95

701

125-100-250L

125

5”

100

4”

330

742

200

450

102

753

125-100-315

125

5”

100

4”

310

697

185

416

92

679

125-100-315L

125

5”

100

4”

310

697

185

416

92

679

Fv

Fh

Fv

Fh


Forces and moments values are applied to the
whole flanges and not flange-by-flange. For their
sharing out on the pump flanges, refer to standard
NFCR 13 931.

Ensure piping and fittings are

flushed before use.

Ensure piping for hazardous liquids is

arranged to allow pump flushing before removal of
the pump.

4.3.2 Suction piping

4.3.2.1 Design of a flooded suction line
The suction line must be as short and direct as
possible, never mount an elbow directly on the
inlet flange of the pump.

Continuous flow valve

MENBLOC

Non-return valve

Valve

Flooded suction configuration

a) Avoid sharp elbows or sudden changes of

diameter. Use reducers with

20° total angle.

b) Arrange the piping so that there are no air

pockets.

c) If high points cannot be avoided in suction line,

install air relief valves.

d) If a strainer is necessary, its net area should

be three or four times the area of the suction
pipe.

e) If an inlet valve is necessary, choose a model

with straight line flow.

Do not tighten flanges before the

final check (see § 4.3.4).