Fy fz mx, Hf & lf – Flowserve VTP Wet Pit User Manual

Page 33

Advertising
background image

VERTICAL TURBINE PUMPS (VTPS) CENTRIFUGAL PUMPS ENGLISH 71569224

– 10-13

Page 33 of 76

flowserve.com

Table of maximum forces and moments allowed on VTP pump flanges

4.7.2.1

Head

Type

Forces &

Moments

Discharge Head Size mm(in.)

100

(4)

150

(6)

200

(8)

255

(10)

305

(12)

355

(14)

400

(16)

460

(18)

508

(20)

610

(24)

760

(30)

915

(36)

W

Fx

0.53

(120)

0.80

(180)

1.13

(255)

1.47

(330)

1.67

(375)

1.78

(400)

Fy

0.67

(150)

1.00

(225)

1.47

(330)

1.83

(410)

2.00

(450)

2.23

(500)

Fz

0.45

(100)

0.67

(150)

0.94

(210)

1.22

(275)

1.34

(300)

1.45

(325)

Mx

0.50

(370)

0.75

(550)

1.06

(780)

1.37

(1015)

1.52

(1125)

1.59

(1175)

My

0.26

(190)

0.39

(285)

0.53

(390)

0.67

(495)

0.74

(550)

0.78

(575)

Mz

0.37

(275)

0.57

(425)

0.77

(570)

1.04

(770)

1.15

(850)

1.18

(875)

HF

&

LF

Fx

1.07

(240)

1.60

(360)

2.27

(510)

2.94

(660)

3.34

(750)

3.56

(800)

4.23

(950)

4.90

(1100)

5.34

(1200)

6.01

(1350)

7.12

(1600)

8.46

(1900)

Fy

1.34

(300)

2.00

(450)

2.94

(660)

3.65

(820)

4.00

(900)

4.45

(1000)

5.12

(1150)

5.79

(1300)

6.23

(1400)

7.12

(1600)

8.46

(1900)

9.79

(2200)

Fz

0.89

(200)

1.36

(300)

1.87

(420)

2.45

(550)

2.67

(600)

2.89

(650)

3.34

(750)

4.00

(900)

4.45

(1000)

4.90

(1100)

5.56

(1250)

6.23

(1400)

Mx

1.00

(740)

1.49

(1100)

2.11

(1560)

2.75

(2030)

3.05

(2250)

3.18

(2350)

3.66

(2700)

4.06

(3000)

4.47

(3300)

5.42

(4000)

6.50

(4800)

7.60

(5600)

My

0.51

(380)

0.77

(570)

1.06

(780)

1.34

(990)

1.49

(1100)

1.56

(1150)

1.83

(1350)

2.03

(1500)

2.51

(1850)

2.71

(2000)

3.25

(2400)

3.80

(2800)

Mz

0.75

(550)

1.15

(850)

1.54

(1140)

2.09

(1540)

2.30

(1700)

2.37

(1750)

2.71

(2000)

3.05

(2250)

3.39

(2500)

4.07

(3000)

4.88

(3600)

5.70

(4200)

TF

(1)

Fx

1.07

(240)

1.60

(360)

2.27

(510)

2.94

(660)

3.34

(750)

3.56

(800)

4.23

(950)

4.90

(1100)

5.34

(1200)

6.00

(1350)

7.12

(1600)

Fy

1.34

(300)

2.00

(450)

2.94

(660)

3.65

(820)

4.00

(900)

4.45

(1000)

5.12

(1150)

5.79

(1300)

6.23

(1400)

7.12

(1600)

8.46

(1900)

Fz

0.89

(200)

1.34

(300)

1.87

(420)

2.45

(550)

2.67

(600)

2.89

(650)

3.34

(750)

4.00

(900)

4.45

(1000)

4.90

(1100)

5.56

(1250)

Mx

1.00

(740)

1.49

(1100)

2.11

(1560)

2.75

(2030)

3.05

(2250)

3.18

(2350)

3.66

(2700)

4.07

(3000)

4.47

(3300)

5.42

(4000)

6.50

(4800)

My

0.51

(380)

0.77

(570)

1.06

(780)

1.34

(990)

1.49

(1100)

1.56

(1150)

1.83

(1350)

2.03

(1500)

2.51

(1850)

2.71

(2000)

3.25

(2400)

Mz

0.75

(550)

1.15

(850)

1.54

(1140)

2.09

(1540)

2.30

(1700)

2.37

(1750)

2.71

(2000)

3.05

(2250)

3.39

(2500)

4.07

(3000)

4.88

(3600)

UF

Fx


CONTACT FLOWSERVE CUSTOMER SERVICE

Fy
Fz

Mx


CONTACT FLOWSERVE CUSTOMER SERVICE

My
Mz

Units: Force (F) in kN (lbf); Moments (M) in kNm (lbf·ft)

1.

Forces and moments shown for TF head are for the discharge flange. For the suction flange, use the values for the next large size
head.

Loads shown are maximum allowable for standard construction. Contact Flowserve if higher values are
required or temperatures are higher than ambient

Advertising
This manual is related to the following products:

VTP