Flowserve VTP Wet Pit User Manual

Page 8

Advertising
background image

VERTICAL TURBINE PUMPS (VTPS) CENTRIFUGAL PUMPS ENGLISH 71569224

– 10-13

Page 8 of 76

flowserve.com

Preventing sparks

1.6.4.5

To prevent a potential hazard from mechanical

contact, the coupling guard must be non-sparking.

To avoid the potential hazard from random induced
current generating a spark, the base plate must be
properly grounded.

Avoid electrostatic charge: do not rub non-metallic

surfaces with a dry cloth; ensure cloth is damp.

For ATEX applications the coupling must be selected
to comply with 94/9/EC. Correct coupling alignment
must be maintained.

Additional requirement for metallic pumps on
non-metallic base plates
When metallic components are fitted on a non-
metallic base plate they must be individually earthed.

Preventing leakage

1.6.4.6

The pump must only be used to handle liquids

for which it has been approved to have the correct
corrosion resistance.

Avoid entrapment of liquid in the pump and associated
piping due to closing of suction and discharge valves,
which could cause dangerous excessive pressures to
occur if there is heat input to the liquid. This can occur if
the pump is stationary or running.

Bursting of liquid containing parts due to freezing
must be avoided by draining or protecting the pump
and ancillary systems.

Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be
monitored.

If leakage of liquid to atmosphere can result in a
hazard, install a liquid detection device.

Maintenance to avoid the hazard

1.6.4.7

CORRECT MAINTENANCE IS REQUIRED TO

AVOID POTENTIAL HAZARDS WHICH GIVE A
RISK OF EXPLOSION

The responsibility for compliance with maintenance
instructions is with the plant operator.

To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or

adversely affect the ambient conditions. Where there
is a risk from such tools or materials, maintenance
must be conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted. (See section 6, Maintenance.)

Safety Labels Summary

1.7

Nameplate

1.7.1
For details of nameplate, see the Declaration of
Conformity,

or separate documentation included with

these User Instructions.

Safety labels

1.7.2

Oil lubricated units only:

Specific Machine Performance

1.8

For performance parameters see section 1.5, Duty
conditions

. When the contract requirement specifies

these to be incorporated into User Instructions these
are included here. Where performance data has
been supplied separately to the purchaser these
should be obtained and retained with these User
Instructions if required.

Noise Level

1.9

Attention must be given to the exposure of personnel
to the noise, and local legislation will define when
guidance to personnel on noise limitation is required,
and when noise exposure reduction is mandatory.
This is typically 80 to 85 dBA.

Advertising
This manual is related to the following products:

VTP