Flowserve VTP Wet Pit User Manual

Page 36

Advertising
background image

VERTICAL TURBINE PUMPS (VTPS) CENTRIFUGAL PUMPS ENGLISH 71569224

– 10-13

Page 36 of 76

flowserve.com

Examples of typical pre-lube methods used in the industry are as follows.

Example (a)

TANK

PIPING MUST BE
MINIMUM LENGTH AS

GATE VALVE SHOULD
MAX. DISCHARGE

1" MIN PIPE

PRESSURE

Pre-lubrication recommended tank volume for pumps started at rated RPM’s for all cases of pre-lubrication
methods suggested in this section

Depth to water level

(at the time of starting the

pump) m (ft)

Pre-Lubrication tank

size.m

3

(US gal)

More than

Upto

0 9

(30)

0

9 (30)

30 (100)

0.19 (50)

30 (100)

60 (200)

0.38 (100)

60 (200)

150 (500)

0.75 (200)

Example (b)

STARTUP

LEVEL

MAX

LEVEL

GATE VALVE SHOULD WITHSTAND
MAX. DISCHARGE PRESSURE

PIPING MUST BE KEPT TO
MINIMUM LENGTH AS POSSIBLE

DRAIN

PLUG

25 mm (1in.) MIN

PIPE LINE

LEVEL
GAUGE

LUBRICATION

TANK

VENT

Advertising
This manual is related to the following products:

VTP