PACKING RING SIZES

Packing Dimensions

Shaft size

Packing ring size

Outside diameter of

packing

mm (in.)

mm (in.)

mm (in.)

25 (1.00)

9.65 (0.38)

44.4 (1.75)

32 (1.25)

9.65 (0.38)

50.8 (2.00)

38 (1.50)

11.17 (0.44)

60.4 (2.38)

43 (1.69)

12.70 (0.50)

68.3 (2.68)

49 (1.93)

12.70 (0.50)

74.6 (2.93)

56 (2.20)

12.70 (0.50)

81.0 (3.19)

62 (2.44)

12.70 (0.50)

87.3 (3.43)

68 (2.68)

12.70 (0.50)

93.7 (3.69)

75 (2.95)

12.70 (0.50)

100.0 (3.93)

82 (3.22)

12.70 (0.50)

107.9 (4.24)

89 (3.50)

15.74 (0.62)

120.6 (4.74)

95 (3.75)

15.74 (0.62)

127.0 (5.00)

102 (4.00)

15.74 (0.62)

133.3 (5.24)

114 (4.50)

15.74 (0.62)

146.0 (5.74)

Startup with new packing

6.2.5.4
Check to see that the by-pass line (if used) is
connected and the packing gland is loose. Start
pump and allow it to run for 20 to 30 minutes. Do not
tighten the gland during this "run-in" period even if
leakage is excessive. Should the new packing cause
excessive heating during "run-in", flush the shaft and
packing box area with cold water or shut the pump
down and allow to cool.

For all repair instructions please call

Flowserve representative or customer service with
the order no. and unit details for specific repair
instruction literature.

All repair work to be carried out by trained and
authorized personnel only. Flowserve’s written
permission may be required for any
disassembly/repair of the pump that is still under
warranty.

Spare Parts

6.3

Ordering of spares

6.3.1
Flowserve keep records of all pumps that have been
supplied. When ordering spare parts we need the
following information:

1. pump type and pump size
2. serial number of the pump
3. number of the required spare parts
4. reference number and name of the part as listed

in the part list or in the sectional drawing


The pump size and serial number are as shown on
the pump nameplate.

How to select recommended spares

6.3.2

Generally a list of spare parts supplied along with the
pump that shows the parts that are included in each of
the following two classes of recommended spares. If
you do not find such documentation please contact
Flowserve for the list.

Class I minimum

6.3.2.1
Suggested for Domestic Service when pump is
handling clean non-corrosive liquids and where
interruptions in service are not important.

Class II average

6.3.2.2
Suggested for Domestic Service when pump is
handling abrasive or corrosive liquids and where some
interruptions in continuity of service are not
objectionable.

Please contact Flowserve Sales Representative in
your area to review the spares best suited to meet
your requirements.

Storage of spare parts

6.3.3
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6-month intervals.

Recommended Spares and

6.4

Consumables


A list of spares and consumables are generally
included along with this User Instructions and other
documents that you have received along with the
pump and is made specifically to your order. In the
event that the list is not found, please contact
Flowserve with pump type and order no.

Tools Required

6.5


Standard tools needed to maintain this pump are
follows.

 Open ended spanners / wrenches (standard size

range)

 Socket spanners / wrenches (standard size

range)

 Allen

keys/wrenches

 Standard range of screw drivers

 Soft

mallet


For drive collet pumps:

 Collet

driver

 Sand collar (if not provided on the unit)

 Tie down bolt