Flowserve LR Worthington User Manual

Page 16

Advertising
background image

LR, LRV, LLR and LR-S USER INSTRUCTIONS ENGLISH 71569088 08-10

Page 16 of 48

flowserve.com

Type and size

Maximum forces (F) in kN (lbf) and maximum moments (M) in kNm (lbf·ft)

Suction

Discharge

Fx

Fy

Fz

Mx

My

Mz

Fx

Fy

Fz

Mx

My

Mz

1.5LLR-7

1.47

(330)

1.15

(260)

1.34

(300)

0.85

(630)

0.45

(330)

0.6

(440)

0.77

(170)

0.88

(190)

0.64

(140)

0.44

(320)

0.24

(170)

0.32

(230)

1.5LLR-10

2.35

(520)

1.85

(410)

1.34

(300)

1.36

(1 000)

0.72

(530)

0.96

(700)

0.77

(170)

0.88

(190)

0.64

(140)

0.44

(320)

0.24

(170)

0.32

(230)

2LLR-9 to

2LLR-11

2.35

(520)

1.85

(410)

1.34

(300)

1.36

(1 000)

0.72

(530)

0.96

(700)

1.03

(230)

1.17

(260)

0.85

(190)

0.59

(430)

0.32

(230)

0.43

(310)

3LLR-11

2.94

(660)

2.31

(510)

1.68

(370)

1.70

(1 250)

0.90

(660)

1.20

(880)

1.54

(340)

1.76

(390)

1.28

(280)

0.88

(640)

0.48

(350)

0.64

(470)

4LLR-11

4.41

(990)

3.47

(770)

2.52

(560)

2.55

(1 880)

1.35

(990)

1.80

(1 320)

1.92

(430)

2.20

(490)

1.60

(360)

1.10

(810)

0.60

(440)

0.80
(590)

2.5LR-10

2.35

(520)

1.85

(410)

1.34

(300)

1.36

(1 000)

0.72

(530)

0.96

(700)

1.25

(280)

1.43

(320)

1.00

(230)

0.72

(530)

0.39

(280)

0.52

(380)

2.5LR-13

2.94

(660)

2.31

(510)

1.68

(370)

1.70

(1 250)

0.90

(660)

1.20

(880)

1.25

(280)

1.43

(320)

1.00

(230)

0.72

(530)

0.39

(280)

0.52

(380)

3LR-9

2.94

(660)

2.31

(510)

1.68

(370)

1.70

(1 250)

0.90

(660)

1.20

(880)

1.54

(340)

1.76

(390)

1.28

(280)

0.88

(640)

0.48

(350)

0.64

(470)

3LR-12

3.68

(820)

2.88

(640)

2.10

(470)

2.12

(1 560)

1.12

(820)

1.50

(1 100)

1.54

(340)

1.76

(390)

1.28

(280)

0.88

(640)

0.48

(350)

0.64

(470)

4LR-10

3.68

(820)

2.88

(640)

2.10

(470)

2.12

(1 560)

1.12

(820)

1.50

(1 100)

1.92

(430)

2.20

(490)

1.60

(360)

1.10

(810)

0.60

(440)

0.80

(590)

4LR-11

to 4LR-14

4.41

(990)

3.47

(770)

2.52

(560)

2.55

(1 880)

1.35

(990)

1.80

(1 320)

1.92

(430)

2.20

(490)

1.60

(360)

1.10

(810)

0.60

(440)

0.80

(590)

5LR-10

to 5LR-15

4.41

(990)

3.47

(770)

2.52

(560)

2.55

(1 880)

1.35

(990)

1.80

(1 320)

2.40

(540)

2.75

(610)

2.00

(450)

1.37

(1 010)

0.75

(550)

1.00

(730)

5LR-19

5.88

(1 320)

4.62

(1 030)

3.36

(750)

3.40

(2 500)

1.80

(1 320)

2.40

(1 770)

2.40

(540)

2.75

(610)

2.00

(450)

1.37

(1 010)

0.75

(550)

1.00

(730)

6LR-10

to 6LR-16

5.88

(1 320)

4.62

(1 030)

3.36

(750)

3.40

(2 500)

1.80

(1 320)

2.40

(1 770)

2.88

(640)

3.30

(740)

2.40

(540)

1.65

(1 210)

0.90

(660)

1.20

(880)

6LR-18

6LR-18S

7.35

(1 650)

5.78

(1 300)

4.20

(940)

4.25

(3 100)

2.25

(1 650)

3.00

(2 200)

2.88

(640)

3.30

(740)

2.40

(540)

1.65

(1 210)

0.90

(660)

1.20

(880)

8LR12/14

7.35

(1 650)

5.78

(1 300)

4.20

(940)

4.25

(3 100)

2.25

(1 650)

3.00

(2 200)

3.84

(860)

4.40

(990)

3.20

(720)

2.20

(1 620)

1.20

(880)

1.60

(1 180)

8LR18S

8LR-20

8.82

(1 980)

6.93

(1 550)

5.04

(1 130)

5.10

(3 760)

2.70

(1 990)

3.60

(2 650)

3.84

(860)

4.40

(990)

3.20

(720)

2.20

(1 620)

1.20

(880)

1.60

(1 180)

8LR-23S

7.35

(1 650)

5.78

(1 300)

4.20

(940)

4.25

(3 100)

2.25

(1 650)

3.00

(2 200)

3.84

(860)

4.40

(990)

3.20

(720)

2.20

(1 620)

1.20

(880)

1.60

(1 180)

10LR-14/16

10LR-14S

8.82

(1 980)

6.93

(1 550)

5.04

(1 130)

5.10

(3 760)

2.70

(1 990)

3.60

(2 650)

4.80

(1 080)

5.50

(1 230)

4.00

(900)

2.75

(2 020)

1.50

(1 100)

2.00

(1 470)

10LR-17/18

10LR-18S

10.30

(2 310)

8.09

(1 800)

5.88

(1 320)

5.95

(4 380)

3.15

(2 300)

4.20

(3 100)

4.80

(1 080)

5.50

(1 230)

4.00

(900)

2.75

(2 020)

1.50

(1 100)

2.00

(1 470)

12LR-14S

10.30

(2 310)

8.09

(1 800)

5.88

(1 320)

5.95

(4 380)

3.15

(2 300)

4.20

(3 100)

5.76

(1 300)

6.60

(1 480)

4.80

(1 080)

3.30

(2 430)

1.80

(1 320)

2.40

(1 770)

Notes:
1) F = External force (tension or compression).

M = External moment, clockwise or counter-clockwise.
Sign convention follows ISO1503 and ISO13709/API610.

2) Forces and moments may be applied simultaneously in any

direction.

3) Values apply to all materials.
4) Higher loads may be applicable, if direction and magnitude of

individual loads are known, but these need written approval
from Flowserve Pumps.

5) Pumps must be on rigid foundations and baseplates must be

fully grouted


6) Pump/baseplate should not be used as pipe anchor. Suction

and discharge piping should be anchored as close as possible
to the pump flanges to reduce vibration and prevent strain on
the pump casing. Expansion joints are recommended. They
must be properly tied and located on the side of the pipe anchor
away from the pump.

7) The pump mounting bolt torques specified must be used to

prevent relative movement between the pump casing and
baseplate. (See section 6.6, Fastener torques.) The bolt
material must have a minimum yield strength of 600 N/mm

2

(87 000 lb/in.

2

).

Advertising
This manual is related to the following products: