Flowserve VF User Manual

Page 24

Advertising
background image

VF USER INSTRUCTIONS ENGLISH 71561233 - 11/09

Page 24 de 32

Lubrification frequency in hours*

Pump type

730 min

-1

970 min

-1

1450 min

-1

Quantity

(gr)

VF 40-20

3 stages

8000

35

VF 40-20

> 3 stages

8000

100

VF 60-18

3 stages

8000

35

VF 60-18

> 3 stages

8000

100

VF 78-37

8000

100

VF 95-27

8000

100

VF 180-27

8000

8000

100

VF 190-19

8000

100

VF 185-35

1 stage

8000

100

VF 185-35

> 1 stage

7500

180

VF 250-43

1 stage

8000

100

VF 250-43

>1 stage

7500

180

VF 240-51

1 stage

8000

100

VF 240-51

> 1 stage

7500

180

VF 300-37

7500

180

VF 310-25

7500

180

VF 460-31

8000

7500

180

VF 550-29

1 stage

8000

180

VF 550-29

>1 stage

3500

60

* At least once a year

The grease used in factory for first filling is:

SHELL ALVANIA R2

Its equivalents:

MOBIL : Mobilux EP 2,

TOTAL : Multis 2,

ELF : ELF MULTI

Grease nipple

6.2.2 Routine inspection (daily / weekly)

The following checks should be

made and the appropriate action taken to remedy
any deviations:

a) Check the behaviour of the pump while

running: noise level, vibrations, bearings
temperature, flow rate and pressure.

b) Check that there are no abnormal fluid or

lubricant leaks (static and dynamic seals) and
that any sealant systems (if fitted) are full and
operating normally.

c) Check the level and condition of oil lubricant.

On grease lubricated pumps, check running
hours since last recharge of grease or
complete grease change.

6.2.3 Periodic inspection (6 monthly)

a)

Check foundation bolts for

security of attachment and corrosion.

b) Check pump running records for hourly usage

to determine if bearing lubricant requires
changing.

c) The coupling should be checked for correct

alignment and worn driving elements.

If a check shows a bad running of the

motor pump unit, the user must:

a)

Refer to the "fault finding chart"

chapter 7 of this leaflet to apply the
recommended solutions.

b) Ensure that your equipment corresponds to

the arrangements of this leaflet.

c) Contact FLOWSERVE after-sales Department

if the problem persists.

Advertising