7 faults; causes and remedies – Flowserve VF User Manual

Page 27

Advertising
background image

VF USER INSTRUCTIONS ENGLISH 71561233 - 11/09

Page 27 de 32

7 FAULTS; CAUSES AND REMEDIES

Insufficient flow rate

Irregular pump running

Driver overloaded

Mechanical seal leak

Equipment vibration

Excessive pump casing temperature

POSSIBLE CAUSES

SOLUTIONS

Air bubbles in pipes

- Check and deaerate the pipes

Suction level too low

- Check the available NPSH > the required NPSH

- Check valves and strainers

- Check the immersion head of the suction valve

Wrong rotation

- Reverse 2 phases on motor terminal boxes

The motor is running on 2 phases only

- Check and control the motor electrical power supply

Motor running too low

- Check the connection in the terminal box according to the
voltage

Total manometric head system higher than pump
differential head

- Check the discharge head

- Check the head losses in discharge pipes (partly closed
valve, foreign particles, back pressure too high)

- Modify the installation or change the pump set

Total manometric head system lower than pump
differential head

-Throttle at discharge valve or trim the impeller (contact our
local agent)

Pipes (valves, filter...)

- Control, dismantle and clean

Insufficient flow rate

- Check the discharge pipe (valves, back pressure)

Worn wear-ring surfaces

- Foresee pump mending: CONSULT FLOWSERVE

Seizure, jamming

- CONSULT FLOWSERVE

Excessive strains on flanges

- Check the flange connections and eliminate strains (pipe
positionning or elastic sleeves mounting)

Defective gland packing on the shaft

- Check and replace all the gland packings parts

- Mechanical seal: CONSULT FLOWSERVE

Defective motor bearings

- CONSULT FLOWSERVE

Specific gravity or viscosity of liquid too high

- Consult our local agent to analyse the problem

Misalignment

- Check the alignment of the pump and of its driver

Foundations not sufficiently rigid

- Check the setting of baseplates: tightening, bad
adjustment, seal


Insufficient pressure


Pump looses prime after starting


POSSIBLE CAUSES

SOLUTIONS

Rotation speed too low (check the driver)

- Check the connection in the terminal box according to the
voltage

Mechanical defects

- CONSULT FLOWSERVE

Suction level too low

- Check the available NPSH > the required NPSH

- Reduce geometrical suction lift (diameter increase and
appropriate fitting positions)

- Check valves and strainers

- Check the immersion head of the suction valve

Defective gasket

- CONSULT FLOWSERVE

Advertising