Flowserve VF User Manual

Page 26

Advertising
background image

VF USER INSTRUCTIONS ENGLISH 71561233 - 11/09

Page 26 de 32


6.2.6 Internal coating
If the pump has an internal coating, this coating
must be inspected periodically. Any wear or
cracks of the coating found must be immediately
repaired. Failure to do this may lead to accelerated
wear of the coating during operation and corrosion
of the exposed base metal, depending on the
material and pumped liquid. Special attention must
be paid to the coating edges. Any loss of coating
material is considered to be normal wear and tear
on the pump and is not considered as warranty.
Flowserve has applied the coatings according to
the supplier's instructions but will not be held
responsible for coating wear or cracks that may
develop over time

.

6.3 Spare parts


6.3.1 Ordering of spares

Flowserve keeps records of all pumps that have
been supplied. When ordering spares the following
information should be quoted.

1) Pump serial number.
2) Pump size.
3) Part name
4) Part number

The pump size and serial number are shown on
the pump nameplate.

To ensure continued satisfactory operation,
replacement parts to the original design
specification should be obtained from Flowserve.
Any change to the original design specification
(modification or use of a non-standard part) will
invalidate the pumps safety certification.

6.3.2 Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6 monthly intervals.

6.4 Recommended spares

1500, 2110, 2130, 2261, 2450, 2461, 2472, 3011,
3400, 4130, 4134, 4610, 9302

a) Destroy all the gaskets after dismantling,

replace them when reassembling.

b)

IT IS RECOMMENDED THAT

BEARINGS ARE NOT REUSED AFTER ANY
REMOVAL FROM THE SHAFT.

c) After serving during two years, replace the

gland packing.

6.5 Disassembly

Refer to section 1.6, Safety, and section 6

Maintenance, before dismantling the pump.

Before dismantling the pump for

overhaul, ensure genuine Flowserve replacement
parts are available. Refer to sectional drawings for
part numbers and identification.

REPAIR OF THE PUMP

If the pump presents abnormalities or a

persistent malfunction, contact immediately:

FLOWSERVE

After-sales Service

Tel.: 02 43 40 57 57

(33) 2 43 40 57 57

Fax.: 02 43 40 58 17

(33) 2 43 40 58 17

According to the After-sales Service instructions,
disassembly will be limited to the dismantling of
the pump.

a)

DISCONNECT THE UNIT

FROM POWER.

b) Close the inlet valve (if fitted) and outlet valve.
c) Wait for the moment when the pump casing is

cooled and at ambient temperature.

d)

DRAIN PUMP.

e) Dismantle inlet and outlet pipeworks as well

as all pipeworks.

f)

REMOVE PUMP TAKING INTO

ACCOUNT SAFETY (§ 1) AND HANDLING
(§ 2.2) PROCEDURES.

ANY DISASSEMBLY, REPAIR OR

REASSEMBLY WILL BE CARRIED OUT UNDER
FLOWSERVE' RESPONSABILITY, EITHER
DIRECTLY BY THE AFTER-SALES SERVICE
OR BY OTHER FLOWSERVE-AGENTS WHO
WILL GET THE REQUIRED INSTRUCTIONS
AND APPROVALS. THIS IS THE CASE OF
AUTHORIZED REPAIRERS WHOSE
ADDRESSES AND TELEPHONE NUMBERS
WILL BE GIVEN ON REQUEST.

Advertising