FRBHJC USER INSTRUCTIONS ENGLISH 71569179 11-04

Page 9 of 36

®

1.8 Specific machine performance

For performance parameters see section 1.5, Duty
conditions
. When the contract requirement specifies
these to be incorporated into User Instructions these
are included here. Where performance data has been
supplied separately to the purchaser these should be
obtained and retained with these User Instructions if
required.

1.9 Noise level

When pump noise level exceeds 85 dBA attention must
be given to prevailing Health and Safety Legislation, to
limit the exposure of plant operating personnel to the
noise. The usual approach is to control exposure time
to the noise or to enclose the machine to reduce
emitted sound. You may have already specified a
limiting noise level when the equipment was ordered,
however if no noise requirements were defined then
machines above a certain power level will exceed 85
dBA. In such situations consideration must be given to
the fitting of an acoustic enclosure to meet local
regulations.

Pump noise level is dependent on a number of factors -
the type of motor fitted, the operating capacity,
pipework design and acoustic characteristics of the
building. The levels specified in the table below are
estimated and not guaranteed.

The dBA values are based on the noisiest ungeared
electric motors that are likely to be encountered. They
are Sound Pressure levels at 1 m (3.3 ft) from the
directly driven pump, for "free field over a reflecting
plane". For Estimating Lwa sound power level (re 1pW)
add 14Dba to the sound pressure value.

If a pump unit only has been purchased, for fitting with
your own driver, then the "pump only" noise levels from
the table should be combined with the level for the
driver obtained from the supplier. If the motor is driven
by an inverter, it may show an increase in noise level at
some speeds. Consult a Noise Specialist for the
combined calculation.

&

For units driven by equipment other than

electric motors or units contained within enclosures,
see the accompanying information sheets and
manuals.


FRBH pump size

Sound Pressure
dBA @ 1 m (3 ft)

Sound Power

dBA

Pump speed -rpm

2 FRBH-121

75

89

1780

3 FRBH-121

75

89

1780

3 FRBH-101

75

89

1780

3 FRBH-141

77

91

1780

4 FRBH-111

77

91

1780

4 FRBH-141

78

92

1780

6 FRBH-111

80

93

1780

6 FRBH-142

81

95

1780

8 FRBH-182

83

98

1180

8 FRBH-152

85

99

1780

10 FRBH-182

85

99

1180

6FRBH-183

85

100

1780

8FRBH-183

86

101

1780