Table 4.20 – Possible values of DI_Actuator_Alarms_Chan

Value

Definition

0x01

Local ESD Active

0x02

Remote ESD Active

0x04

Open Inhibit Active

0x08

Close Inhibit Active

0x05

Local ESD Active + Open Inhibit Active

0x09

Local ESD Active + Close Inhibit Active

0x06

Remote ESD Active + Open Inhibit Active

0x0A

Remote ESD Active + Open Inhibit Active

0x0C

Open Inhibit Active + Close Inhibit Active

4.2.6 DI_Disc_User_Input_Chan

Table 4.21

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Discrete

Input #8

Discrete

Input #7

Discrete

Input #6

Discrete

Input #5

Discrete

Input #4

Discrete

Input #3

Discrete

Input #2

Discrete

Input #1

4.2.7 DI_Read_Disc_Output_Chan

Table 4.22

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Reserved

Relay

Discrete

Output #7

Relay

Discrete

Output6 #

Relay

Discrete

Output #5

Relay

Discrete

Output #4

Relay

Discrete

Output #3

Relay

Discrete

Output #2

Relay

Discrete

Output #1

4.2.8 DO_Position_Chan

Table 4.23

Value

Definition

0x00

Stop

0x01

Open

0x02

Close

0x03

– 0xFF

Reserved

4.2.9 DO_ESD_Chan (Read Only)

Table 4.24

Value

Definition

0x00

Disable Network ESD

0x01

Enable Network ESD

DO_ESD_Chan can’t be written directly via the DeviceNet network, it is Read-Only. The attribute
Enable_Broadcast_ESD_Ctrl defines if a device is part of the broadcast ESD control scheme from Bit-
Strobe Connection or not. The resulting DO_ESD_Chan is defined in the following table.

The MX allows the standard I/O connection to assert ESD, or the broadcast bit strobe connection to
assert ESD.