2 behavior – Flowserve Limitorque MX DeviceNet Field Unit User Manual

Page 30

Advertising
background image

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05

30

International Product Name (Attribute ID 13)

Semaphore (Attribute ID 14)

are not supported by DeviceNet Limitorque Interface.

Some of the instance attributes do not have any external interfaces, these values are managed directly in
the DeviceNet Slave Software.

NOTE 1: The Vendor ID is managed by the ODVA. Flowserve has already obtained a valid Vendor ID.
The Vendor ID will be assigned during compile time as a constant of the DeviceNet Slave Software and
stored in Flash-Memory of the DeviceNet Limitorque Interface. Thus it cannot be altered during runtime.

NOTE 2: The Product Code of the DeviceNet Limitorque Interface has already been assigned by
Flowserve. It typically maps to a catalog or model number. The Product Code will be assigned during
compile time as a constant of the DeviceNet Slave Software and stored in Flash-Memory of the
DeviceNet Limitorque Interface. Thus it cannot be altered during runtime.

NOTE 3: The Revision of the DeviceNet Limitorque Interface. Has already been assigned by Flowserve.
It typically links to the revision control system of a company. The format of the revision is Major.Minor,
starting with 1.1, because 0 is not allowed in CIP. The default value for this attribute is therefore 0x0101.
The revision must match the entry of the EDS-File delivered with the DeviceNet Limitorque Interface.
The Revision will be assigned during compile time as a constant of the DeviceNet Slave Software and
stored in Flash-Memory of the DeviceNet Limitorque Interface. Thus it cannot be altered during runtime.

NOTE 4: The Status represents the current status of the device. Important here are the bits 8 to 11
which make faults visible to the user.

NOTE 5: The Serial Number is used in conjunction with the Vendor ID to form a unique identifier for
each device. Flowserve is responsible for guaranteeing the uniqueness of the serial number across all of
its devices. The SMT Main Board will initialize the DeviceNet Limitorque Interface with data every time a
loss of communication condition between the DeviceNet Limitorque Interface and the SMT Main Board
had occurred. A part of this initialization data will be a unique board ID coming from the SMT Main
Board. Upon reception of this unique board ID from the SMT Main Board, the DeviceNet Limitorque
Interface will construct a Serial Number value. The transducer/spi software will then get the currently
stored serial number value from the DeviceNet stack, compare it to the one just constructed based on
the data from the main board, and if different, set the new value in the Identity Object / EEPROM. Also,
if the values were different, the transducer / spi software will then request that the DeviceNet board
reset to it’s “factory default” non-volatile condition (exception: the serial number in EEPROM is not
overwritten again).

NOTE 6: The Product Name should represent a short description of the product/product family
represented by the product in attribute 3. It is limited to 32 characters. The product name should default
to “Limitorque”. However, at “spi initialization time”, the product name attribute can be updated by some
kind of API function call by the transducer / spi driver.

4.4.2 Behavior

Table 4.36 – Behavior

Event

Source

Description

Power Applied

DeviceNet Limitorque Interface Connect DeviceNet bus power

Passed Tests

DeviceNet Limitorque Interface No errors detected during internal selftest