5 drive sleeve and housing cover disassembly, 6 torque nut disassembly (drive 1 option) – Flowserve L120 Series Limitorque Actuation Systems User Manual

Page 29

Advertising
background image

29

Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15

flowserve.com

6.5 Drive Sleeve and Housing Cover Disassembly

Piece numbers refer to Figure 5.2.

1. Remove Upper Ball Bearing (piece 17), Bevel Gear (piece 18), Declutch Spring (piece 24), Clutch

Sleeve (piece 19), and Key (piece 23).

2. Remove Lower Ball Bearing (piece 16).

3. Spirolox Retainer (piece 22) may now be removed by inserting small flat blade

screwdriver under the end of the ring and prying the first layer from the groove.
Continue around the ring until it is free from the groove.

4. Remove the Worm Gear (piece 21) and the Lug Ring (piece 20).

5. Handwheel Adapter (piece 26) and Seal (piece 42) can be removed from Housing Cover (piece 27)

by removing Retaining Ring (piece 28).

6.6 Torque Nut Disassembly (Drive 1 Option)

For applications requiring torque only, the L120 series actuator can be supplied without the thrust
base option. The torque nut is driven by the drive sleeve lugs and held in place by the torque bushing
connector.

Figure 6.1 – L120-10 through 40 standard and extended drive sleeve assembly

Unless otherwise stated, piece numbers refer to Figure 6.1.

Standard Drive Sleeve
To remove the Torque Nut (piece 95), remove Retaining Ring (piece 183) and drop the torque nut out
the bottom of the Drive Sleeve (piece 25 of Figure 5.2).

25

95

183

25

95

183

97

99

96

98

Extended

Standard

Piece Quantity

Description

25

1

Drive Sleeve

95

1

Torque Nut

96

1

Torque Bushing Connector

97

1

Torque Bushing Washer

98

1

Retaining Ring

99

1

Elastic Stop Nut

183

1

Retaining Ring

Advertising