Limitorque LY Series: LY 1001, LY 2001 and LY 3001 FCD LMENIM1501-00 – 11/11

flowserve.com

2. If Torque Nut has been bored and keywayed by Limitorque, verify dimensions and keyway location

for proper compatibility with the valve stem.

3. If Torque Nut has not been bored and keywayed by Limitorque, it is provided solid (blank) to allow

customer to custom key and bore up to the maximum permissible sizes as listed in Table 5.1.

Table 5.1 – Mounting Base Dimensions

Unit Type and Size

Maximum Bore

inch (mm)

Maximum Keyway

inch (mm)

LY 1001

1-1/8, dia (28 dia)

1/4 x 1/8, (6 x 3)

LY 2001/3001

2-3/8, dia (60 dia)

5/8 x 1/16 (15 x 7.5)

NOTE: Before keywaying, match the Torque Nut with the Valve Stem to ensure proper keyway location. Use the

Keyway Index Mark (LY 1001 only) for locating appropriate keyway location.

Figure 5.2 – LY Keyway Locations

A

B

C

D

LY 1001 Keyway

Location Marks

D

A

B

C

Torque Nut

Stop Lug

LY 2001/3001 Keyway

Location Positions