54

LY 3001 Handwheel Assembly

18. Install the Handwheel Gear Assembly (pieces #119, 35, and 37).

19. Install the Handwheel Pinion and Idler (piece #43) and Idler Shaft (piece #42).

20. Install the Handwheel Assembly (pieces #146, 41, 112, 136, 39, 34, 137, 116, 115, 38, and 36).

21. Install Screws (pieces #63 and 65) and Lockwashers (pieces #64 and 66) to secure the Handwheel

Assembly onto the housing.

Install Input Worm Motor Pinion Assembly

22. Install Input Worm Motor Pinion Assembly (piece #52, 53, 124, and 31) into the Housing.

23. Install Housing Seal (O-Ring) (piece #131).

Grease Unit

24. Grease unit with the properly recommended grease. (See Section 7.1, Lubrication.)

Install Top Plate

25. Install Top Plate (piece #2) and Hardware (piece #88 and 89).

NOTE:

If Top Plate will not fit properly, check Bearing (piece #33) and Declutch Shaft (piece #44) for

proper alignment into Top Plate molding.

Install Torque Switch Assembly, Motor Assembly, and Limit Assembly

26. Install Torque Switch Assembly with Gasket (piece #8) and Hardware (piece #97 and 98).

27. Install Limit Switch (piece #7) with Hardware (piece #79 and 80).

28. Reconnect Limit Switch, Torque Switch, and Terminal Strip. Refer to the actuator wiring diagram for

proper wiring configuration.

Install Control Cover

NOTE: Before installing the Control Cover, reset the Limit Switches and Mechanical Stops. Recheck
motor for proper rotation.

29. Install Cover O-Ring (piece #130).

30. Install Control Cover (piece #3) with Hardware (piece #67 and 68).