2 setting the open limit switch – Flowserve LY Series Limitorque User Manual

Page 21

Advertising
background image

21

Limitorque LY Series: LY 1001, LY 2001 and LY 3001 FCD LMENIM1501-00 – 11/11

flowserve.com

5.8.2 Setting the OPEN Limit Switch

NOTE: When setting the OPEN Limit Switch, be careful not to rotate the CLOSE Limit Cam; rotating it
will change the adjustments you previously made on the CLOSE Limit Switch.

1. Put the actuator into MANUAL operation by moving the Declutch Lever in the direction of the

arrow on the lever until the Declutch Lever locks in place. If Declutch Lever is difficult to move, see
Section 6.4, Manual Operation for instructions to release the Declutch Lever.

2. Turn the Handwheel to move the valve to the full OPEN position.

NOTE:

Most applications require turning the Handwheel CCW to obtain the full OPEN position. The

Drive Sleeve and Limit Cams also rotate in CCW rotation to the OPEN position. If your application is
configured differently, keep in mind the descriptions in this manual will describe rotation directions
opposite of your application.

3. Loosen Setting Nut (piece #7-10) located at the top of the switch bracket. (See Figure 5.7.)

4. Rotate the OPEN Limit Cam CCW through the high side to the trip point until the Switch Plunger is

released. This causes the N.O. contact to open. There will be no electrical continuity at the trip point
when measuring with an ohmmeter between the common lead and the N.O. lead; you may also hear
a faint “click” at the trip point.

NOTE:

During actuator operation, when the Switch Plunger trips, the N.O. contact is released,

causing the Limit Switch to stop the actuator in the OPEN position.

Figure 5.9 – Setting OPEN Limit Cam

5.

Retighten Setting Nut (piece #7-10).

NO

NC

CO

M

NO

NC

CO

M

High Side

Rotate CCW to reach

OPEN Trip Point

Switch Plunger

OPEN Limit Cam

OPEN microswitch

position while valve

is traveling from CLOSED

toward the OPEN position

OPEN microswitch

position while valve

has reached the OPEN

position and microswitch

has tripped

Switch Plunger

OPEN Trip Point

position (“click”)

High Side

OPEN Limit Cam

Advertising