7.4 Troubleshooting

c

WARNING: Be aware of electrical hazards within the actuator and high-pressure hazards of the
attached valve or other actuated device when installing or performing maintenance on the LY
actuator.

Symptom

Possible Cause

Corrective Action

Unit will not operate electically

No power to unit

a. Verify power supply is

electrically correct and present
at actuator.

b. Verify power leads are

connected in accordance with
the applicable wiring diagram.

c. Inspect for blown fuse, tripped

circuit breaker or overload or
open disconnect switch.

Loose or incorrect wiring

Check wiring for proper wiring
connection in accordance with the
applicable wiring diagram. Check
also for tight connections.

Limit Switches not set or
incorrectly set

Check Limit Switch development
incorrectly set for agreement with
the applicable wiring diagram.
If not set properly, follow
instructions in Section 5.7, Limit
Switch and Mechanical Stop
Settings.

Foreign material on switch
contacts preventing good
electrical contact

Check continuity of microswitch
with an ohmmeter.

Motor runs, but no output from
unit

Actuator not coupled properly to
output

Inspect Torque Nut and Valve
Shaft to verify key is in place and
properly staked.

Worm gear worn out

Remove Worm Shaft Assembly
in accordance with Section 7.3.1,
Disassemble Unit LY 1001 or
Section 7.3.3, Disassemble Unit
LY 2001/3001 as applicable.
Inspect worm gear for unusual
wear. If excessive wear has
occurred, replace the Worm Shaft
Assembly.

Torque Nut disengaged from Drive
Sleeve

Verify Torque Nut properly
installed in accordance with
Section 5.4, Installation
(continued) Overview Step No. 1.

Motor runs, but no output from
unit

Damaged gearing

Disassemble actuator in
accordance with Section 7.3.1,
Disassemble Unit LY 1001 or
Section 7.3.3, Disassemble Unit
LY 2001/3001 as applicable.
Inspect gearing for rough or
damaged spots. Replace as
required. Most often, damaged
spots are seen in motor gear set.