Flowserve NRG 16-40 User Manual

Page 5

Advertising
background image

5

Explanatory Notes

Scope of supply

NRG 16-40
 Level electrode type NRG 6-40

 S. S. joint ring D 7 x 3 mm to DIN 7603 (made of .430), bright annealed

 Terminating resistor 0

 Installation manual

NRG 17-40
 Level electrode type NRG 7-40

 S. S. joint ring D 7 x 3 mm to DIN 7603 (made of .430), bright annealed

 Terminating resistor 0

 Installation manual

NRG 19-40
 Level electrode type NRG 9-40

 S. S. joint ring D 7 x 3 mm to DIN 7603 (made of .430), bright annealed

 Terminating resistor 0

 Installation manual

NRG 111-40
 Level electrode type NRG -40

 S. S. joint ring D 33 x 39 mm to DIN 7603 (made of .430), bright annealed

 Terminating resistor 0

 Installation manual

Description

The level electrode NRG ...-40 works according to the conductivity measurement principle.

The NRG ...-40 is designed for use in conductive liquids to detect the minimum liquid level:

One level with

one switchpoint.

The NRG ...-40 is used in combination with switching controller NRS -40 or NRS -40. or further

system components. NRG ...-40 in conjunction with the associated control equipment constitutes a

water level limiter with periodic self-testing routine (SMART function) in accordance with TRD 604,

sheet  and  and EN regulations. The level data are transferred from the electrode NRG ...-40 to the

control unit via a CAN bus using the CANopen protocol.

Advertising