Technical data – Flowserve NRG 16-40 User Manual

Page 7

Advertising
background image

7

NRG 16-40, NRG 17-40, NRG 19-40, NRG 111-40

Type Approval Nº

TÜV · SWB / SHWS · 0-403

EG BAF-MUC 0 0 0388 00
Service pressure

NRG 16-40, PN 40

NRG 17-40, PN 63

NRG 19-40, PN 160

NRG 111-40, PN 320

3 bar g (464 psig)

60 bar g (870 psig)

00 bar g (450 psig)

83 bar g (65 psig)

at 38°C

at 75°C

at 3 °C

at 357°C

Connection

Screwed ¾" BSP, EN ISO 8- (NRG 6-40, NRG 7-40, NRG 9-40)

Screwed " BSP, EN ISO 8- (NRG -40)
Materials

Terminal box: Die cast aluminium 3.6 (G AlSi8Cu3)

Stem: S. S. .457 (X6CrNiMoTi7  )

Measuring electrode: S. S. .440 (X5CrNiMo7  )

Electrode insulation: Gylon

®

(NRG 6-40, NRG 7-40, NRG 9-40)

Electrode insulation: PEEK (NRG -40)
Lengths supplied

500 mm, 000 mm, 500 mm, 000 mm, 500 mm, 3000 mm
Sensitivity of response

> 0.5

µS/cm at 5°C.

Supply voltage

8 – 36 V DC (coming from NRS -40 / NRS -40.)
Current consumption

35 mA
Fuse

Electronic thermal fuse T

max

= 85 °C, hysteresis K

Hysteresis

- K
Electrode voltage

 V

ss

Data exchange

CAN bus to DIN ISO 898, CANopen protocol
Indicators and adjustors

One 0-pole code switch for node ID and baud rate settings

One wire link (for switching between electrode  and electrode )

Electric connection

M  sensor connector, 5 poles, A-coded,

M  sensor jack, 5 poles, A-coded
Protection

IP 65 to DIN EN 6059
Max. admissible ambient temperature

70 °C
Weight

approx. .5 kg