Fronius Acctiva Professional 35A User Manual

Page 27

Advertising
background image

25

EN

If the battery voltage selection window does not open, then the battery is in a state of ex-
treme deep-discharge (less than 2 V). In this case, it is advisable to use Refresh mode to
reactivate the deep-discharged battery. For more information, see the "Refresh mode" sec-
tion.
-

A corresponding warning appears

If Charging mode is still required despite the battery being in a state of extreme deep-dis-
charge
-

Acknowledge the warning via the OK button using the Stop/Start key.

-

Use the Up/Down keys to select the correct battery voltage in the subsequent selec-
tion window.

-

Confirm the selection using the Stop/Start key

-

A set of four bars shows the state of
charge of the battery (e.g. three bars
represent a state of charge of 80%).

-

All four bars are continuously display-
ed.

-

The state of charge is 100%.

-

The battery is ready to use.

-

The battery may remain connected to
the charger for any length of time.

-

Conservation charging counteracts
battery self-discharge.

Disconnect the charger
-

Disconnect the black charger lead from the negative pole (-) on the battery

-

Disconnect the red charger lead from the positive pole (+) on the battery

Interrupting
charging

Confirm the selection using the Stop/Start key

6

CAUTION! Risk of sparks if the charger leads are disconnected too soon. Before
disconnecting the charger leads, press the Stop/Start key to finish charging.

To end charging:

-

Press the Stop/Start key

7

8

NOTE! Danger of damage to connection sockets and plugs. Do not disconnect or
unplug charger leads while charging.

Press the Stop/Start key while charging

-

The process is interrupted

2