Buffering (trickle) mode – Fronius Acctiva Professional 35A User Manual

Page 29

Advertising
background image

27

EN

Buffering (Trickle) mode

General informa-
tion

Buffering (Trickle) mode is intended exclusively for relieving the battery during a vehicle
diagnosis or software update. The power used over an extended period of time must be
less than the charger's maximum output current (35 A), otherwise the battery will be
drained. Buffering (Trickle) mode is not suitable for fully charging the battery.

Buffering the bat-
tery

Plug in charger mains plug

Connect battery - the de-energised charger leads mean there are no sparks when
connecting to the battery, even if the charger is already connected to the mains supply.
-

Connect the red charger lead to the positive pole (+) on the battery

-

Connect the black charger lead to the negative pole (-) on the battery

The charger automatically identifies the
battery, e.g. 12 V, and starts the buffering
process after 5 seconds.

If the battery voltage is not correctly identi-
fied (e.g. in the event of a deeply dischar-
ged battery), you have 5 seconds to enter
the correct battery voltage, as follows:

If the selection window for the battery voltage does not open, then the battery is in a state
of extreme deep-discharge (less than 2 V). In this case, buffering is not permitted. We rec-
ommend the battery be replaced.

CAUTION! Risk of damage when attempting to charge a faulty battery. Before
buffering, ensure that the battery is fully functional.

Select Buffering mode using the up/down keys.

1

2

3

CAUTION! Risk of damage if the wrong voltage is set. Always ensure that the cor-
rect battery voltage is set.

Set the correct battery voltage using the up/down keys (6 V /
12 V / 24 V).

Confirm the selection using the Stop/Start key

4

5

Advertising