Synergic lines

Safety

Available charac-
teristics

Charging characteristic IUoU:

I

1

= Main charging current

U

1

= Final charging voltage

U

2

= Conservation charging voltage

WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Follow the battery manufacturer's instructions. The battery must not be
connected to the charger when setting parameters.

Operating mode Battery Charac-

teristic

I

1

U

1

[6/12/24V] I

2

U

2

[6/12/24V] Ex.

Charging

WET

IUoU

35* 7.2/14.4/28.2

-

6.75/13.5/27

Yes

AGM

6.84/13.68/
27.36

GEL

7.05/14.1/28.2

USER

2-30

1.9-29.9

Buffering (Trickle)
mode

All

IU

35

6.75/13.5/27

-

-

Yes

Refresh

WET

IUIoU

35* 7.2/14.4/28.8

4

6.75/13.5/27

No

AGM

2

6.84/13.68/
27.36

GEL

7.05/14.1/28.2

USER

IUa

35** 2-34

-

-

Yes

Power supply
mode

None

IU

35

6.75/13.5/27

-

-

Yes

Battery changing All

IU

35

6.75/13.5/27

-

-

No

I

1

Main charging current [A]
maximum device current: 35 A

*

20 A per 100 Ah of specified battery capacity

**

10 A per 100 Ah of specified battery capacity

U

1

Final charging voltage [V]

I

2

Recharging current [A per 100 Ah of specified battery capacity]

U

2

Conservation charging voltage [V]
Automatic switchover to pulse charge conservation after 12 hours, apart
from user application in Expert mode

Ex.

Adjustable final charging voltage and conservation charging voltage in Ex-
pert mode. For trained professionals only

I

1

U

1

U

2