Charging errors

No. 30: Timeout in the corresponding char-
ging phase

Remedy:
-

Set Ah to correct value

-

Check for parallel consumers (car ra-
dio, etc.)

-

Battery temperature too high

No. 31: Too many Ah charged, too few Ah set

Remedy:
-

Set Ah to correct value

-

Check for parallel consumers (car radio, etc.)

-

Replace battery if it appears to be faulty

No. 32: Optional external temperature sensor has tripped due to undertemperature

Remedy:
-

Charge the battery in a more suitable area

No. 33: Optional external temperature sensor has tripped due to overtemperature

Remedy:
-

Allow battery to cool, or charge battery in a more suitable area

No. 34: Battery voltage set too high

Remedy:
-

Set the correct battery voltage

No. 35: Voltage below target voltage after 2 h - Refresh mode in analysis phase

Remedy:
-

Check for parallel consumers (car radio, etc.)

-

Replace battery if it appears to be faulty

No. 36: Cell short circuit

Remedy:
-

Check for parallel consumers (car radio, etc.)

-

Replace battery if it appears to be faulty

No. 37: Conservation charge current too high

Remedy:
-