Troubleshooting – Fronius Acctiva Professional 35A User Manual

Page 41

Advertising
background image

39

EN

Troubleshooting

Safety

Protective equip-
ment

Charger leads connected to wrong poles,
reverse polarity protection has tripped

Remedy:
-

Connect battery poles correctly

Short circuit in the charging terminals or
charger lead, short-circuit detection active

Remedy:
-

Check charger leads, contacts and
battery poles

Mains fault - mains voltage outside the tole-
rance range

Remedy:
-

Check mains conditions

Battery overvoltage

Remedy:
-

Set the correct operating mode and
voltage

WARNING! An electric shock can be fatal. Before opening the device:
-

Unplug the device from the mains

-

Disconnect battery connection

-

Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again

-

Using a suitable measuring instrument, check to make sure that electrically
charged parts (e.g. capacitors) have been discharged

CAUTION! Failure to connect a correctly-dimensioned earth lead may result in
serious injury or damage. The housing screws provide a suitable PE conductor
connection for earthing (grounding) the housing and must NOT be replaced by
any other screws that do not provide a reliable PE conductor connection.

Advertising